WPT compensation capacitors, SS and SP.
Resonant capacitors for series–series and series–parallel links from L1, L2 and M or k — with the voltage each capacitor has to survive.
WPT compensation capacitor calculator
- Primary capacitor C₁
- 146.1 nF
- Secondary capacitor C₂
- 146.1 nF
- Voltage across C₁ (RMS)
- 64.09 Vpeak 90.63 V
- Voltage across C₂ (RMS)
- 16.43 Vpeak 23.23 V
- Current in C₂ (RMS)
- 1.282 A
- Secondary coil current (RMS)
- 1.282 A
- Load voltage / current
- 12.82 V / 1.282 A
- Output power
- 16.43 W
- Input resistance at resonance
- 657.2 mΩ
Lossless coils and capacitors, sinusoidal (first-harmonic) operation, RMS values.
How do you calculate WPT compensation capacitors?
The compensation capacitors of a wireless power link are chosen to resonate each coil at the operating frequency. Series–series (SS) compensation is the usual default because its capacitors do not depend on coupling or load, while series–parallel (SP) compensation makes the primary capacitor depend on the coupling. This calculator handles both topologies from L1, L2 and either M or k, at any frequency from kHz to MHz. Enter the primary current and load resistance to see the RMS and peak voltage across each capacitor, the secondary currents and the delivered power, so you can pick capacitors with the right voltage rating. AirInduct Sim computes L1, L2 and M from coil geometry, and its AI Copilot sizes SS, SP and LCC networks from them.
Worked example
Two 24 µH coils at k = 0.2 (M = 4.8 µH), 85 kHz, 5 A RMS in the primary, 10 Ω load:
| SS: C₁ = C₂ | 146.1 nF |
|---|---|
| SS: voltage across C₁ (RMS / peak) | 64.09 V / 90.63 V |
| SS: load current, output power | 1.282 A, 16.43 W |
| SP: C₁ | 152.2 nF |
| SP: C₂ | 146.1 nF |
| SP: load current, output power | 1 A, 10 W |
The SP primary capacitor is 4.2 % larger than the SS one at this coupling, so using the SS value would detune the input. Capacitor voltage grows with frequency, inductance and current, so check it again whenever you scale the design.
When you need the full simulator
This calculator is free to use and answers one question at a time. The full AirInduct Sim simulator goes further:
- L₁, L₂ and M computed from the actual coil geometry, so the capacitors match the coils you will build.
- SS, SP and LCC–LCC capacitors with efficiency, coil losses and a frequency-splitting check (Copilot link analysis).
- Class-D and Class-E inverter matching with ZVS checks, plus synchronous rectifier analysis.
- SPICE netlist export to verify the tank in your circuit simulator.
More free calculators
- Mutual inductance calculatorM between two circular or square coils from turns, size, gap and lateral offset, or from k, L1 and L2.
- Coupling coefficient calculatork from coil geometry or from L1, L2 and M, plus a k-versus-gap curve.
- Helmholtz coil calculatorCentre field, required current and optimal spacing for circular and square Helmholtz pairs, with axial uniformity.
- Square Helmholtz coil calculatorSquare pairs: centre field, current for a target field, spacing and the uniform region.
- WPT efficiency calculatorMaximum link efficiency from k and Q, the optimal load and the k needed for a target efficiency.
- Skin depth calculatorSkin depth of copper, aluminium and other conductors versus frequency and temperature, with the round-wire AC/DC resistance ratio.
- PCB spiral inductance calculatorInductance of square, hexagonal, octagonal and circular planar spirals by the modified Wheeler and current-sheet formulas.
- PDN target impedance calculatorTarget impedance from rail voltage, ripple and transient step, with bulk capacitance and decap count estimates.
Frequently asked questions
Why is the SP primary capacitor different from the SS one?
With a parallel-tuned receiver, the reflected load changes what the primary sees, so the primary capacitor depends on the coupling. An SP primary capacitor is only exactly right at one coupling. In SS compensation the primary capacitor does not depend on coupling or load.
Should I use SS or SP compensation?
SS is the usual default: both capacitors are independent of coupling and load, which makes it tolerant of misalignment. SP makes the receiver behave like a current source, which suits some battery-charging and constant-current loads, but its primary tuning shifts with coupling. LCC networks add more freedom at the cost of more components.
How do I size the capacitor voltage rating?
A series capacitor sees a voltage equal to that across the coil it tunes, which can reach hundreds of volts or more in kilowatt-class systems. Use the peak value (1.41 × RMS for a sine wave), add margin for misalignment and tolerance, and choose a capacitor type rated for that voltage and RMS current at your frequency, typically film or C0G/NP0 ceramic.
What frequency should I use?
It depends on the standard and power level. SAE J2954 light-duty EV charging uses a nominal 85 kHz (79–90 kHz band); Qi phone charging operates roughly in the 87–205 kHz range; AirFuel resonant systems use 6.78 MHz. Higher frequency shrinks the capacitors, but increases switching and AC-resistance losses.