Mutual inductance calculator, from coil geometry.
Enter two circular or square coils, the gap and any misalignment. M is computed from the coils themselves, not from k, instantly in your browser.
Mutual inductance calculator
- Mutual inductance M
- 6.754 µH
- Per turn pair (M / N₁N₂)
- 67.54 nH
Air-core coils in parallel planes, offset along one side.
What is the mutual inductance of two coils?
Mutual inductance M is the voltage induced in one coil per unit rate of change of current in the other, and for two air-core coils it depends only on geometry: turns, size, shape, the gap between them and any lateral misalignment. It is measured in henries. This calculator works from the coils themselves: enter the shape, turns and size of each coil, the gap and any misalignment, and it returns M instantly in your browser. AirInduct Sim goes further in its full simulator, adding spiral and multi-turn layouts, field maps and the circuit around the link.
Worked example
Two identical circular coils, 10 turns each, radius 50 mm, 20 mm apart:
| Coaxial (no offset) | 6.754 µH |
|---|---|
| 25 mm lateral offset | 4.959 µH |
| Drop from misalignment | 26.6 % |
The same gap with other shapes:
| Two 100 mm square coils, 10 turns each | 8.268 µH |
|---|---|
| 50 mm-radius circle (10 turns) over an 80 mm square (5 turns) | 2.922 µH |
A half-radius misalignment costs about a quarter of the mutual inductance here. For the coupling coefficient, use the coupling coefficient calculator, which includes the self-inductances.
When you need the full simulator
This calculator is free to use and answers one question at a time. The full AirInduct Sim simulator goes further:
- Planar spiral (DTC) and Helmholtz windings modelled turn by turn, not as one lumped coil.
- Full 3D field maps — surface, heatmap and contour — so you can see where the flux goes.
- Parameter sweeps over gap, offset and size, and an optimizer that searches for the best geometry.
- Matching networks, rectifier and thermal analysis, plus PDF, KiCad, DXF and SPICE export.
More free calculators
- Coupling coefficient calculatork from coil geometry or from L1, L2 and M, plus a k-versus-gap curve.
- Helmholtz coil calculatorCentre field, required current and optimal spacing for circular and square Helmholtz pairs, with axial uniformity.
- Square Helmholtz coil calculatorSquare pairs: centre field, current for a target field, spacing and the uniform region.
- WPT compensation capacitor calculatorSeries–series and series–parallel resonant capacitors from L1, L2, M and frequency, with capacitor voltage stress.
- WPT efficiency calculatorMaximum link efficiency from k and Q, the optimal load and the k needed for a target efficiency.
- Skin depth calculatorSkin depth of copper, aluminium and other conductors versus frequency and temperature, with the round-wire AC/DC resistance ratio.
- PCB spiral inductance calculatorInductance of square, hexagonal, octagonal and circular planar spirals by the modified Wheeler and current-sheet formulas.
- PDN target impedance calculatorTarget impedance from rail voltage, ripple and transient step, with bulk capacitance and decap count estimates.
Frequently asked questions
How do I calculate mutual inductance from coil dimensions?
Enter the shape, size and turns of each coil, the gap between them and any lateral offset. The calculator returns M directly, and the chart shows how it changes with misalignment. Turn counts multiply: doubling the turns on one coil doubles M.
Why does mutual inductance fall with lateral misalignment, and can it become negative?
As the receiver slides sideways, part of it moves outside the transmitter and catches return flux, which points the other way. M therefore drops and, at a large enough offset, crosses zero and turns negative. Use the offset chart above to find the null for your own geometry.
Does mutual inductance scale with the number of turns?
Yes. M grows with the product of the two turn counts, while the coupling coefficient stays nearly constant. Turns set the impedance level; geometry sets the coupling.
How accurate is this compared with a 3D field solver?
For air-core coils with compact windings the results agree with the full simulator. Real coils differ when the winding is wide compared with the gap, when turns are spread out as a planar spiral, or when ferrite or metal is nearby. In those cases use the full simulator, which models each turn individually.